Solution Characteristic
one.Ideal for the 6000rpm high velocity
2.Substantial power & large torque
3.Substantial performance
4.Modest size
5.Reduced sound reduced vibration
6.Patented cooling construction
seven.Simple maintenance and long daily life time
8.Efficient Coaxial Fan

Specs
Model sort: SRPM205L8XO37B
Voltage: 380V AC
Rated Energy: 37KW
Fee Torque : fifty eight.9N.m
Working speed: 6000rpm
Efficiency: ninety six.2%
Isolation: H/F
Pole Quantity: eight
Cooling Method: Air Cooling 
Situation Signal: Resolver (optional)
Set up Technique: B5/B35
Weight:≤47KG

Application
Followers,Pumps,Compressors

Other Versions you will be interested in:

Motor kind Voltage
(V AC)
Rated electrical power
(kW)
Rated torque (N.m) Rated velocity
(rpm)
Efficiency
(%)
Support Factor Insulation Ingress defense Pole Quantity Excess weight
(kg)
Cooling Technique Position Signal  Set up Technique
SRPM205L8XF18.5 380 18.5 35.3 5000 ninety six one.two H/F IP54 eight 38 Air Cooling Resolver B35
SRPM205L8XF22 380 22 36.three 5800 ninety six one.two H/F IP54 eight forty one Air Cooling Resolver B35
SRPM205L8XF30 380 thirty 49.four 5800 ninety six.1 one.two H/F IP54 eight 46 Air Cooling Resolver B35
SRPM205L8XF37 380 37 fifty five 6500 ninety six.3 1.two H/F IP54 8 50 Air Cooling Resolver B35
SRPM205L8XF45 380 45 66.1 6500 96.3 1.two H/F IP54 8 76 Air Cooling Resolver B35
SRPM205L8XF55 380 55 eighty.eight 6500 96.three 1.2 H/F IP54 8 85 Air Cooling Resolver B35
SRPM205L8XF75 380 seventy five one hundred ten 6500 ninety six.5 one.two H/F IP54 8 97 Air Cooling Resolver B35
SRPM314L8X135 380 one hundred thirty five 253 5100 97.5 one.2 H/F 8 Refrigerant Resolver

FAQ
1. Can performanent magnet synchronous motor be utilised as generator? 

No. Long term magnet synchronous motor is completely diverse from generator. It is only ac motor that outputs speed and torque to push electric powered units, but not electrical power provide. 
 
2. Why can not immediately use a few phase ac supply voltage to start permanent magnet synchronous motor? 
Becuase rotor is with huge innertia, and magetic documents spins so quickly that static rotor has no way to spin with magetic submitted. 
 
three. Any particular technical request on this motor’s VFD driver? And Do you have these kinds of driver? 
Everlasting magnet synchronous motor’s driver must be vector handle VFD with unique internal software, such as Siemens 6SE70 sequence, Yakawa CR5 series, ABB ACS800 sequence, Mitsubishi A740 collection, B&R P84 and P74 series, and so on.. Indeed, our MH300 sequence VFD matches with this motor. 
 
four. Is there any protective actions to protect permanent magnet rotor from failure? 
Of course, every single long term magnet rotor passes corrossion resistance, regularity, high temperature demagnetization examination, linear demagnetization take a look at, and so forth. Its demagnetization index is inside two%. But if operating surroundings is critical oxiditive corrosion, kindly suggest for higher defense level. 
 
five. In which is this permanent magnet synchronous motor typically utilised to? 
This everlasting magnet synchronous motor is generally utilized to variable frequency pace situation.
 

Advanced Test Resources Synchronous Reluctance AC Pm Motor